HOMEOWNER GUIDE · PRODUCTION

Are your solar panels producing less than promised? Here's how to check.

Your monitoring app shows one number. Your contract shows another. Here's how to compare them fairly, and how to tell a normal variation from a real shortfall.

Checking production is the most useful thing a solar homeowner can do, and most people never do it. It takes about 20 minutes and two numbers.

Step 1: Find the number you were promised

Look through your contract, proposal and any design documents for one of these:

  • Estimated annual production, in kWh per year. This is the clearest number.
  • Offset, a percentage such as "105% offset." This means the system was expected to produce that percentage of your yearly usage. To turn it into kWh, multiply it by the usage figure the proposal used.
  • Guaranteed production, common in leases and PPAs. This is often lower than the estimate. Write down both if you have both.

If the number in a change order differs from the original contract, write down both. Systems sometimes change between signing and installation without the production estimate or the price changing with them.

Step 2: Find what the system actually produced

Open your monitoring app (Enphase, SolarEdge, Tesla or similar) and find total production for the last full 12 months. Most apps have a year view or let you export monthly totals.

No app access? Many inverters show a lifetime kWh counter on the unit or its display. Your installer is also usually able to give you access to monitoring.

Your smart-meter data (in much of Texas, through Smart Meter Texas) shows how much you exported and bought. It's useful, but it doesn't show total production, because power used inside the house never reaches the meter.

Step 3: Compare them the right way

  • Use a full year. Summer months make a system look great and winter months make it look bad. Twelve months evens that out.
  • Allow for normal variation. Weather shifts a typical year by a few percent, and panels lose roughly half a percent of output per year as they age.
  • Watch for offset tricks. If the offset was calculated on a low usage figure, a system can be "100% offset" on paper while covering much less of what you actually use.
Rule of thumb: if a full year of production is within about 5% of the estimate, the system is probably performing as designed. If it's 15% or more short, something is wrong, and it's usually documentable.

Common causes of a shortfall

Shading that wasn't modeled

Trees, chimneys, neighboring buildings and even vent pipes cast shade at different times of year. A design that ignores shading can overstate production badly, especially with string inverters, where one shaded panel can drag down others.

Change orders

Panels get moved from a south-facing roof to an east or west face, or the panel count drops because of fire setbacks or roof space. If the production estimate wasn't updated, the promise no longer matches the system on your roof.

Equipment failures

A failed inverter or several dead microinverters can quietly remove a chunk of production. Monitoring apps often show this as individual panels reporting zero.

Monitoring that stopped reporting

Sometimes the system is fine and the app is wrong because the gateway lost its Wi-Fi connection. Check whether the app shows recent data before assuming the worst.

What to do if you find a gap

  1. Screenshot the yearly and monthly production totals and save the contract pages that show the estimate.
  2. Notify the installer in writing (email is fine) and keep a copy. Ask whether there's a production or performance guarantee and how claims work.
  3. Calculate the shortfall in kWh, then multiply by your electricity rate to get a rough yearly dollar cost.
  4. If the installer's answer doesn't match your contract, or you want the math checked independently, send it to me for a free review.

Also see: why your electric bill may still be high even if production looks fine.

Common questions

How much below the estimate is normal for solar production?

Year-to-year weather typically moves production up or down by a few percent, and panels lose roughly half a percent of output per year as they age. A shortfall of 15%, 30% or more over a full year is not weather. It points to a design, installation or equipment issue.

Can I check my solar production without the monitoring app?

Partly. Your utility or smart-meter data shows how much power you exported to the grid and how much you bought, but not the total your panels made, because some of it was used inside the house. The inverter itself usually has a lifetime production counter you can read.

General information, not legal or financial advice. Every contract is different. SolarFCG does not sell solar and accepts no installer, dealer or lender compensation.

NO SALES PITCH

Want someone to check your numbers?

Send your contract, monitoring data and electric bills. I'll read them myself and tell you whether there's a gap worth documenting. The first look is free.

Have Mike Review My Case — Free